Item | Specifications |
---|---|
Temperature Range | -20 to 60 °C – specified range -40 to 71 °C – operating range |
Pressure Range | 100 Mpa |
Humidity |
|
IP rating | IP68, 2 m, 24 h |
Depth | 500 m |
Vibration | 3g RMS – 20Hz to 2 kHz as per MIL-STD-810G (A2 range options) |
Shock | 500 g for 0.3 ms |
Item | Specifications |
---|---|
Operating Temperature Range | -20 to 60 °C – specified range -40 to 71 °C – operating range |
Storage Temperature Range | -40 to 85°C |
Pressure Range | 100 Mpa |
Humidity |
|
IP rating | IP68, 2 m, 24 h |
Depth Rating | 500 m |
Vibration | 3g RMS – 20Hz to 2 kHz as per MIL-STD-810G (A2 range options) |
Shock | 500 g for 0.3 ms |
Salt Spay | 168 h, 5% concentration according to IEC/EN/NF Standard |
Certifications |
|
Calibration interval |
|
Item | Specifications |
---|---|
Conducted Emissions | |
Conducted Immunity | |
Radiated Emissions | |
Radiated Immunity | |
Common standards |
|
Item | Specification |
---|---|
Calibration interval |
|
Electronic equipment such as discrete components, hybrid devices, integrated circuits, printed circuit assemblies can be permanently damaged or destroyed when near or in contact with electro-statically charged objects.
Standards | Title |
---|---|
EN 61340-5-1 (2016) | Electrostatics. Protection of electronic devices from electrostatic phenomena – General Requirements |
EN 61340-5-2(2007) | Electrostatics. Protection of electronic devices from electrostatic phenomena – User guide |
IEC 61340-5-3(2015) | Electrostatics, Protection of electronic devices from electrostatic phenomena – Properties and requirements classification for packaging intended for electrostatic discharge sensitive devices |
ESD sensitive devices must be handled only in static-protected environment.
According to reference standards above, each ESD protection equipment such as grounding strap, bench matting, floor matting and ground cord must be tested before handling ESD sensitive devices. In addition, it is strongly recommended to wear ESD smocks during all service procedures.
ESD sensitive devices are supplied in ESD protective packaging such as ESD shielding bags.
ESD sensitive devices and ESD protective packaging are identified with specific labels.
ESD sensitives devices must be stored in ESD protective packaging before final assembly.
Quanta product line complies with European Union (EU) Directive 2002/95/EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS Directive).
Conformity reports are available upon request.
Quanta product line complies with European Union (EU) Directive 2006/1907/EC on the production and use of chemical substances, and their potential impacts on both human health and the environment.
Quanta product line comply with the European Union (EU) Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). The purpose of this Directive is the prevention of waste electrical and electronic equipment, and in addition, the reuse, recycling and other forms of recovery of such wastes so as to reduce the disposal of waste. If purchased in the European Union, please return the products at the end of its life to the supplier from which it was purchased.