Environmental Conditions

Environmental specifications

Operating Temperature range-40°C to 85°C
Storage Temperature range-40°C to 85°C
Humidity (% rh)Max 85%Non-condensing
Operating Vibration 20Hz to 2000 Hz; 10g RMSMIL-STD-810
Operating shocks survivability> 100g 11ms (powered on)

Highest test performed. 

Actual survivability is higher ; contact us if you need tests at higher amplitude

Accelerometer channels saturates above 40g

MTBF>4 Million hours

Ground Mobile (GM)

MIL-HDBK-217 part count method + Supplier MTBF

EMC

StandardDescriptionSpecificationsCriteriaVerdict
CEI 61000-4-2 - Electrostatic discharge immunity testElectrostatic discharge±6kV contactBCompliant
±8kV AirBCompliant
CEI 61000-4-3 - Radiated, radio-frequency, electromagnetic field immunity testElectromagnetic fieldsFrequency (MHz)Severity (V/m)ACompliant
80 MHz - 2.0 GHz10 V/m
2.0 GHz - 6 GHz3 V/m
50 kHz - 80 MHz3 V/m
CEI 61000-4-4 - Electrical fast transient/burst immunity testFast transient bursts common mode1 kV (5/50ns 5kHz)BCompliant
CEI 61000-4-6 - Immunity to conducted disturbances, induced by radio-frequency fieldsCurrents induced by radio-frequency fields10 V/m (fréquences de spots: 2 MHz, 3 MHz, 4 MHz, 62 MHz, 82 MHz, 126 MHz, 165 MHz, 188 MHz, 22 MHz, 25 MHz)ACompliant
CEI 61000-4-8 - Power frequency magnetic field immunity testMagnetic field immunity3 A/m (50 Hz / 60 Hz)ACompliant

Voltage interruptions60s (3 interruptions)CCompliant
CISPR 16 / EN 55016-1-2 - Radio-frequency disturbance characteristics / Conducted emissionsConducted EmissionsFrequency (MHz)Quasi-peak limit (dBµV)BCompliant
0.01 - 0.15 MHz96 - 50
0.15 - 0.3560 - 50
0.35 - 3050
CISPR 16 / EN 55016-1-4 - Radio-frequency disturbance characteristics / Radiated emissionsRadiated EmissionsFrequency (MHz)

Peak Limit

(dBµV/m)

Average Limit

(dBµV/m)

Quasi-peak Limit

(dBµV/m)

BCompliant
0.15 - 0.3--80 - 52
0.3 - 30--52 - 34
30 - 2000--54
Except (156 - 165)30-24
AThe ME must continue to operate as intended during and after the test.
No performance degradation or loss of function is allowed, relative to the specific hardware standard and the technical specification published by the manufacturer.
BThe ME must continue to operate as intended after the test.
No performance degradation or loss of function is allowed, as specified in the applicable hardware standard and the technical specification published by the manufacturer.
During the test, degradation or loss of function or performance that can self-correct is permitted; however, no modification of the actual operating state or recorded data is allowed.
CTemporary degradation or loss of function or performance is permitted during and after the test if the function self- corrects or can be restored by operating the controls as specified in the applicable hardware standard and the technical specification published by the manufacturer.