IMU Pulse-40 User manual Current: Environmental and EMC PDF Download PDF Download page Environmental and EMC. Current page All pages Environmental and EMC Environmental ConditionsEnvironmental specificationsOperating Temperature range-40°C to 85°CStorage Temperature range-40°C to 85°CHumidity (% rh)Max 85%Non-condensingOperating Vibration 20Hz to 2000 Hz; 10g RMSMIL-ST-STD-810Operating shocks survivability> 100g 11ms (powered on)Highest test performed. Survivability higher ; contact us if you need additional testsSaturation above 40gMTBF>4 Million hoursGround Mobile (GM)MIL-HDBK-217 part count method + Supplier MTBFEMCTestEMC NormTest typeEmission testsEN 55032:2015Radiated disturbanceImmunity testsEN 61000-4-3:2006 +EN 61000-4-3/A1:2008Electromagnetic fieldsEN 61000-4-8:2010Magnetic field immunity ×