Page tree
Skip to end of metadata
Go to start of metadata

Accelerometers specifications

Preliminary

These performance specifications are preliminary and will be confirmed after complete qualification.


TypicalUnitsNotes
Measurement range±40g
Scale Factor error500ppmOver ±1g, one year accelerated aging
Non-linearity (ppm of FS)25ppmOver ±1g, one year accelerated aging
Long-term bias repeatability

1250

µgOne year accelerated aging
In-run bias instability6µgAllan Variance method, constant temperature
Velocity Random Walk0.02m/s/√hAllan Variance method, constant temperature
Noise spectral density40µg/√HzWide-band noise ]0 to 100] Hz
Misalignment1mradOver temperature range
Orthogonality0.07mradOver temperature range
Vibration Rectification Coefficient (VRC)0.03mg/g²10g RMS - random vibrations 20Hz to 2kHz
Bandwidth250Hz-3dB point
Sampling rate4.0kHz

Gyroscopes specifications

Preliminary

These performance specifications are preliminary and will be confirmed after complete qualification.


TypicalUnitsNotes
Measurement range

±499

±4000*

°/s

490 °/s is the default range.

Scale Factor error500ppmOne year accelerated aging
Non-linearity (ppm of FS)25ppmOne year accelerated aging
Long-term bias bias repeatability150°/hOne year accelerated aging
In-run bias instability0.6°/hAllan Variance method, constant temperature
Angular Random Walk0.08°/√hAllan Variance method, constant temperature
Noise spectral density5.0°/h/√HzWide-band noise ]0 to 100] Hz
Misalignment1mradOver temperature range
Orthogonality0.07mradOver temperature range
Vibration Rectification Coefficient (VRC)0.02°/h/g²10g RMS - random vibrations 20Hz to 2kHz
Acceleration sensitivity10°/h/gTested over ±1g
Bandwidth250Hz-3dB point
Sampling rate6.6kHz

4000°/s version is export controlled.

Magnetometers specifications

A set of three Anisotropic Magneto-resistive magnetometers is embedded within the all the Pulse-40. This technology provides a very high sensitivity compared to coil based technologies.

Magnetometer sampling design makes it impossible to reject signal frequencies above 75Hz. User should ensure that high frequency noise is not disturbing magnetometers at the sensor's location.


SpecificationsRemarks
Full scale (Gauss)50
Scale factor stability (%)0.5
Noise (mGauss)3Over 1 to 25 Hz band
Bias stability (mGauss)1
Bandwidth (Hz)22-3dB attenuation
Resolution (mGauss)1.5
Sampling rate (Hz)100
Orthogonality (°)0.1Achievale after magnetic calibration
  • No labels