| Typical | Units | Notes | |
|---|---|---|---|
| Measurement range | ±40 | g | |
| Scale Factor error | 500 | ppm | Over ±1g, one year accelerated aging |
| Non-linearity (ppm of FS) | 25 | ppm | Over ±1g, one year accelerated aging |
| Long-term bias repeatability | 1250 | µg | One year accelerated aging |
| In-run bias instability | 6 | µg | Allan Variance method, constant temperature |
| Velocity Random Walk | 0.02 | m/s/√h | Allan Variance method, constant temperature |
| Noise spectral density | 40 | µg/√Hz | Wide-band noise ]0 to 100] Hz |
| Misalignment | 1 | mrad | Over temperature range |
| Orthogonality | 0.07 | mrad | Over temperature range |
| Vibration Rectification Coefficient (VRC) | 0.03 | mg/g² | 10g RMS - random vibrations 20Hz to 2kHz |
| Bandwidth | 250 | Hz | -3dB point |
| Sampling rate | 4.0 | kHz |
| Info |
|---|
* To comply with dual use export regulation, the standard range variant of the PULSE-40 has a bias superior to 1250µg |
Gyroscopes specifications
...