Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...


TypicalUnitsNotes
Measurement range±40g
Scale Factor error500ppmOver ±1g, one year accelerated aging
Non-linearity (ppm of FS)25ppmOver ±1g, one year accelerated aging
Long-term bias repeatability

1250

µgOne year accelerated aging
In-run bias instability6µgAllan Variance method, constant temperature
Velocity Random Walk0.02m/s/√hAllan Variance method, constant temperature
Noise spectral density40µg/√HzWide-band noise ]0 to 100] Hz
Misalignment1mradOver temperature range
Orthogonality0.07mradOver temperature range
Vibration Rectification Coefficient (VRC)0.03mg/g²10g RMS - random vibrations 20Hz to 2kHz
Bandwidth250Hz-3dB point
Sampling rate4.0kHz
Info

* To comply with dual use export regulation, the standard range variant of the PULSE-40 has a bias superior to 1250µg


Gyroscopes specifications

...