| Warning |
|---|
|
These performance specifications are preliminary and will be confirmed after complete qualification. |
| Typical | Units | Notes |
|---|
| Measurement range | ±40 | g |
|
|---|
| Scale Factor error |
|---|
300| 500 | ppm | Over ±1g, one year accelerated aging |
| Non-linearity (ppm of FS) | 25 | ppm | Over ±1g, one year accelerated aging |
|---|
| Long-term bias repeatability |
|---|
1000* | µg | One year accelerated aging |
| In-run bias instability | 6 | µg | Allan Variance method, constant temperature |
|---|
| Velocity Random Walk | 0.02 | m/s/√h | Allan Variance method, constant temperature |
|---|
| Noise spectral density | 40 | µg/√Hz | Wide-band noise ]0 to 100] Hz |
|---|
| Misalignment |
|---|
0.34| 1 | mrad | Over temperature range |
| Orthogonality | 0.07 | mrad | Over temperature range |
|---|
| Vibration Rectification Coefficient (VRC) | 0.03 | mg/g² | 10g RMS - random vibrations 20Hz to 2kHz |
|---|
| Bandwidth | 250 | Hz | -3dB point |
|---|
| Sampling rate | 4.0 | kHz |
|---|
...
Gyroscopes specifications
| Warning |
|---|
|
These performance specifications are preliminary and will be confirmed after complete qualification. |
| Typical | Units | Notes |
|---|
| Measurement range |
|---|
±490±499 ±4000* | °/s | 490 °/s is the default range. |
| Scale Factor error |
|---|
1000| 500 | ppm | One year accelerated aging |
| Non-linearity (ppm of FS) | 25 | ppm | One year accelerated aging |
|---|
| Long-term bias bias repeatability |
|---|
250| 150 | °/h | One year accelerated aging |
| In-run bias instability | 0. |
|---|
8| 6 | °/h | Allan Variance method, constant temperature |
| Angular Random Walk | 0.08 | °/√h | Allan Variance method, constant temperature |
|---|
| Noise spectral density | 5.0 | °/h/√Hz | Wide-band noise ]0 to 100] Hz |
|---|
| Misalignment |
|---|
0.34| 1 | mrad | Over temperature range |
| Orthogonality | 0.07 | mrad | Over temperature range |
|---|
| Vibration Rectification Coefficient (VRC) | 0.02 | °/h/g² | 10g RMS - random vibrations 20Hz to 2kHz |
|---|
| Acceleration sensitivity | 10 | °/h/g | Tested over ±1g |
|---|
| Bandwidth | 250 | Hz | -3dB point |
|---|
| Sampling rate | 6.6 | kHz |
|
|---|
| Info |
|---|
4000°/s version is export controlled. |
A set of three Anisotropic Magneto-resistive magnetometers is embedded within the all the Pulse-40. This technology provides a very high sensitivity compared to coil based technologies.
| Warning |
|---|
Magnetometer sampling design makes it impossible to reject signal frequencies above 75Hz. User should ensure that high frequency noise is not disturbing magnetometers at the sensor's location. |
| Specifications | Remarks |
|---|
| Full scale (Gauss) | 50 |
|
|---|
| Scale factor stability (%) | 0.5 |
|
|---|
| Noise (mGauss) | 3 | Over 1 to 25 Hz band |
|---|
| Bias stability (mGauss) | 1 |
|
|---|
| Bandwidth (Hz) | 22 | -3dB attenuation |
|---|
| Resolution (mGauss) | 1.5 |
|
|---|
| Sampling rate (Hz) | 100 |
|
|---|
| Orthogonality (°) | 0.1 | Achievale after magnetic calibration |
|---|