Data logging can be done through sbgCenter, a free software included in inertial SDK, available here.

When logging data using sbgCenter, the data will be buffered in RAM and saved to disk at the end of the logging session. So for long data acquisition, please use sbgDataLogger (you can find a similar step by step guide for sbgDataLogger)

If sbgCenter crashes during the logging, all data will be lost. The sbgCenter should not replace a survey logging tool.

Connect to the unit, then start recording by clicking on the recording icon. To stop the recording, please click on the same icon. Then you can play/pause it and save it.

record_

save_

Output format

After saving you *.sbgz project, you will be able to open it as a sbgCenter project, just by double clicking on it. And you'll have access to your configuration on read only mode.

You can also unzip the file and extract from it a binary log and a JSON file of your configuration, that can be used in Qinertia.