The Ekinox Micro is designed to operate in the harshest conditions and has been qualified with military grade standards.
Temperature / pressure / humidity specifications
Item | Specifications | Remarks |
---|---|---|
Operating temperature | -40 to 71°C (-40 to 185°F) | Each Ekinox Micro is individually calibrated and corrected for the entire operating temperature range |
Storage | -40 to 85°C (-40 to 185°F) | |
IP rating | IP-68 (12 hours at 2 meters) | |
Humidity | IP-68, no limit | |
Altitude / pressure | 80km | Due to GNSS export restrictions Pressure vent to prevent low pressure issues |
Maximum velocity | 500 m/s | Due to GNSS export restrictions |
Vibration, shocks and lifecycle
Items | Specifications | Remarks |
---|---|---|
MTBF | > 200,000 hours | Ground Mobile (GM) MIL-HDBK-217 part count method + Supplier MTBF |
Calibration interval | None required, maintenance free | |
Vibrations | 8 g RMS [20Hz - 2kHz] | MIL-STD-810H - Method 514.8, Category 24, |
Shocks | 25g - 11ms | MIL-STD-810H - Method 514.8 ANNEX A |
EMC compatibility
Item | Standard |
---|---|
Directive 2014/53/EU (RED) | |
Safety and health (Art. 3.1a) | EN 62368-1:2014 |
EN 62479:2010 Assessment of the Compliance with Restrictions related to Human Exposure to Electromagnetic Fields | |
Electromagnetic compatibility (Art. 3.1b) | ETSI EN 301 489-1 V2.2.3 (2019-11) |
ETSI EN 301 489-19 V2.1.1 (2019-4) | |
Radio spectrum efficiency (Art. 3.2) | ETSI EN 303 413 V1.2.1 (2021-4) |
FCC (US) | |
Radiated Emissions | FCC 47 CFR PART 15: 2019 |
MIL-STD | |
MIL-STD-461G | CS114 Conducted Susceptibility, Bulk Cable Injection |
CS115 Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation | |
RS103 Radiated Susceptibility, Electric Field | |
CS116 Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads | |
CE102 Conducted Emissions, Radio Frequency Potentials, Power Leads | |
RE102 Radiated Emissions, Electric Field | |
MIL-STD-1275E | Injected Voltage Surges |
Injected Voltage Spikes |