The Stellar-40 is designed to operate in the harshest conditions and has been qualified with military grade standards.

Temperature / pressure / humidity specifications

ItemSpecificationsRemarks
Operating temperature-40 to 71°C (-40 to 185°F)Each Stellar-40 is individually calibrated and corrected for the entire operating temperature range
Storage-40 to 85°C (-40 to 185°F)
HumidityUp to 95% RH, non-condensing
Altitude / pressure80km

Due to GNSS export restrictions

Maximum velocity500 m/sDue to GNSS export restrictions

Vibration, shocks and lifecycle

ItemsSpecificationsRemarks
MTBF

> 175,000 hours

Ground Mobile (GM)

MIL-HDBK-217 part count method + Supplier MTBF

Calibration intervalNone required, maintenance free
Random Vibrations10g RMS [20Hz - 2kHz]

MIL-STD-810H - METHOD 514.6: ANNEX E

Functional test - full sensor performance

7.7g RMS [20Hz - 2kHz]

MIL-STD-810H - METHOD 514.8: 2.1.1.1

Endurance test - 12h - full performance during & after test

Sine Vibrations
MIL-STD-810H - METHOD 514.8: 2.3.2
6g [20 - 3500Hz]Rigid version
6g [300 - 4500Hz]Damped version
Shocks
MIL-STD-810H - Method 514.8 ANNEX A
30g - 11msOperating with full performance
100g - 11ms

Operating with perf degradation (accelerometer overrange)

EMC compatibility

ItemStandard
Directive 2014/53/EU (RED)

Safety and health (Art. 3.1a)

EN 62368-1:2014

EN 62479:2010 Assessment of the Compliance with Restrictions related to Human Exposure to Electromagnetic Fields

Electromagnetic compatibility (Art. 3.1b)

ETSI EN 301 489-1 V2.2.3 (2019-11)

ETSI EN 301 489-19 V2.1.1 (2019-4)

Radio spectrum efficiency (Art. 3.2)

ETSI EN 303 413 V1.2.1 (2021-4)

MIL-STD
MIL-STD-461GCS114 Conducted Susceptibility, Bulk Cable Injection
CS115 Conducted Susceptibility, Bulk Cable Injection, Impulse Excitation
RS103 Radiated Susceptibility, Electric Field
CS116 Conducted Susceptibility, Damped Sinusoidal Transients, Cables and Power Leads
CE102 Conducted Emissions, Radio Frequency Potentials, Power Leads
RE102 Radiated Emissions, Electric Field
MIL-STD-1275EInjected Voltage Surges
Injected Voltage Spikes